How to Stay Warm in a Power Outage Without Risking CO Poisoning

Last updated: 2026-10-30

To heat your house during a power outage, close off one room and keep it warm with layers, blankets, and safe, vented heat, then leave for a warming center if that fails. Do not heat with a gas oven, gas stove, grill, camp stove, or charcoal, and never run a generator inside or near the house. Carbon monoxide has no smell and no color. A power station will not replace your heat: it can run an electric blanket for hours but a 1,500 W space heater for well under an hour. I live in Washington State, and I have not tested the gear named here. The rules below come from CDC, CPSC, Ready.gov, and the Red Cross.

This is not an abstract risk where I live. After a January 1993 storm cut power to an estimated 776,000 people around Puget Sound, CDC documented 44 carbon monoxide poisonings in 17 incidents. Burning charcoal was the source in 11 of those incidents, and gasoline generators in four. Most people sought care overnight in the three nights after the storm. A Washington Department of Health report says the December 2006 Puget Sound windstorm reportedly resulted in eight deaths.

The rules that keep you alive

Never do thisWhat the authority says
Heat with a gas oven or stoveCDC: “Never use a gas range or oven to heat a home.” Ready.gov adds fire, burn, and appliance damage risk
Burn charcoal indoorsCDC: never burn charcoal indoors. CPSC says not in a garage either, even with the door open
Use a camp stove or chemical heater indoorsCDC: never use a portable gas camp stove indoors, and do not use portable flameless chemical heaters indoors
Use outdoor stoves or grills insideRed Cross: no outdoor stoves indoors for heating or cooking
Run a generator inside or close to the houseCPSC: never in a home, garage, basement, crawlspace, shed, or on a porch. Outside only, at least 20 feet away, exhaust pointed away from buildings
Warm up in a car in the garageCDC: never run a car or truck inside an attached garage, even with the door open

CDC says never to run a generator in your home or garage, even if doors and windows are open. That is the part people talk themselves out of. CPSC also says opening windows does not provide enough airflow, and that about 100 people die each year in the U.S. from portable generator carbon monoxide.

Alarms. CDC says to put battery-operated or battery back-up CO detectors near every sleeping area. CPSC says outside sleeping areas and on each floor, and to test them monthly. A hardwired alarm with no battery backup goes quiet with the power, so check yours before the storm.

Symptoms. CDC lists headache, dizziness, weakness, upset stomach, vomiting, chest pain, and confusion, and says they are often flu-like. People who are asleep can die before they feel anything. If an alarm sounds or you suspect CO, get outside immediately, then call 911. Poison Control is 1-800-222-1222.

What works first, with no fuel at all

These come from FEMA’s Stay Safe and Warm toolkit. None of them needs power.

  • Close the vents and shut the doors in rooms you are not using.
  • Put a rolled towel at the bottom of doors to stop drafts.
  • Open blinds or curtains in the day, especially on windows with direct sun, and close them at night.
  • Dress in several layers of loose clothing. FEMA says layering provides better insulation.

The toolkit also says to make the plan before the storm: look up the nearest warming center and know how to get there. If you cannot keep the house warm, go. You can call 211 for help finding one. Ask first if you are bringing pets, because the same toolkit says warming centers may not allow them.

What a power station can and cannot run

A power station burns nothing, so it adds no carbon monoxide of its own. That is its appeal. Its limit is energy. Heat is the most power-hungry thing most homes do.

Here is the math, using Jackery’s 0.85 estimate for conversion loss and capacity and output from our catalog. Jackery uses that factor for its own stations, and I applied it to all of them so the rows compare. The load figures are a Lasko 1500W tower heater and the 200 W rating on a Pure Enrichment queen heated blanket manual, which is the high end of the labels I read. A Beautyrest full-size blanket lists 160 W maximum, so check your own label.

Station (catalog spec)CapacityContinuous output1,500 W space heater200 W electric blanket
EcoFlow RIVER 3245 Wh300 WCannot run itAbout 1 hour
Jackery Explorer 1000 v21,070 Wh1,500 WAbout 36 minutes, at its limitAbout 4.5 hours
BLUETTI AC1801,152 Wh1,800 WAbout 39 minutesAbout 4.9 hours
BLUETTI AC200L2,048 Wh2,400 WAbout 70 minutesAbout 8.7 hours
Anker SOLIX F38003,840 Wh6,000 WAbout 2 hours 10 minutesAbout 16 hours

Read that across. The same battery gives you less than an hour of a space heater or most of a night of an electric blanket. Warm the person, not the room. Remember the 0.85 factor is only an estimate.

I would not pair a space heater with these stations at all. NFPA and CPSC say to plug a heater directly into a wall outlet, never an extension cord or power strip, and NFPA says to keep it at least 3 feet from anything that can burn and to turn it off and unplug it when you leave the room or go to bed. Those rules were written for a wall outlet. A battery that runs the heater for 39 minutes while eating your whole reserve is a poor trade anyway.

That rule also causes a problem with a generator. CPSC wants the generator 20 feet from the house, and it wants heaters off extension cords. An extension cord from the yard to a space heater breaks the second rule to satisfy the first. If you want to heat from a generator, that is a reason to have an electrician connect it properly, not a reason to run a cord through a window.

Solar will not rescue this. At its full rating, a 200 W panel like the BLUETTI PV200 would need nearly six hours to refill the AC180, which is under 40 minutes of heater. Actual winter output will be lower, and an ice storm is exactly when a panel is covered.

The furnace blower: possible, but not a plug-in job

Your gas or propane furnace may have fuel and still not heat. Filterbuy’s outage guide says the blower and controls need electricity, which is why the house goes cold with a full gas line.

The wattage numbers I can give you are rough. Filterbuy reproduces a Massachusetts generator chart that lists furnace fans by horsepower:

Blower motorStarting wattsRunning watts
1/8 hp500300
1/6 hp750500
1/4 hp1,000600
2/5 hp1,400700
3/5 hp2,350875

A real example runs larger than the small end of that chart. The Goodman GM9S96 spec sheet lists 1/2 hp to 1 hp blowers, with minimum circuit ampacity of 10.3 to 16.93 A and a 15 or 20 A overcurrent device. The GM9S92 sheet says 115 VAC. Minimum circuit ampacity is a wiring figure, not running watts, so I will not multiply it into a wattage. Read the rating plate on your own furnace, usually inside the blower door.

If a blower really ran nonstop at 700 W, a full AC180 would last about 1.4 hours, an AC200L about 2.5 hours, and an F3800 about 4.7 hours, again at 0.85. A furnace cycles, so real time would be longer, but I do not have a duty cycle I can cite. The 1,400 W start fits under the 1,800 W output of the AC180. At 3/5 hp, the 2,350 W start is beyond that continuous rating and inside its 2,700 W surge rating, which is not a promise it will start. The 300 W RIVER 3 is out.

Connecting it is the part that needs a professional. The furnace is typically wired to its own circuit, so this is not a matter of plugging in a cord. Washington DOH says the safe way to connect a generator to house wiring is to have a qualified electrician install a power transfer switch, and never to plug a generator into a wall outlet, which can electrocute utility workers or neighbors. A Carrier furnace manual says wiring must follow the National Electrical Code, that polarity must be maintained on the 115 V wiring, and that the cabinet needs an unbroken ground. Hire a licensed electrician or HVAC technician, and ask them whether your furnace will accept your station or generator at all.

Heat is one load among several, so check the rest of the list too. What size power station for home emergencies covers the sizing, and power station safety covers safe use. Our catalog lists the AC180’s operating range as 32 to 104°F, so a station left in a freezing garage may be outside its rating when you need it.

Fireplaces, wood stoves, and propane

Fireplace. FEMA’s toolkit says to make sure the flue is open so smoke can leave and to reduce the risk of carbon monoxide, never leave an open flame unattended, and keep anything that can burn at least three feet from open flames.

Wood stove or kerosene heater. CDC’s winter guidance says to have your chimney or flue inspected each year, put a smoke detector and a battery-operated CO detector near the area being heated, and keep a multipurpose, dry-chemical fire extinguisher close by. CDC says all fuel-burning equipment should be vented to the outside. If you are searching for off grid heating as a permanent answer, a wood stove is the option I would look at first, but it needs a proper install. Ecology says wood stoves in Washington must meet state and EPA standards, so check that and your local building department before you buy.

Washington has one more wrinkle. Under a Stage 1 burn ban, Ecology says no use of uncertified wood stoves or fireplaces, and Stage 2 means no inside burning. The page also says burn bans do not apply to homes with no other source of heat. It does not mention power outages, so call your local clean air agency if you are unsure rather than guessing.

Propane heater. This is the one to read closely. I wrote a separate propane heater guide from the Mr. Heater manual, because the words “indoor safe” do not mean any room at any time. That manual requires vent openings, sets clearances, and says never to operate the heater while sleeping. If the heater you own is marked outdoor use only, it stays outdoors. CDC says all fuel-burning equipment should be vented.

Ice storm notes

The National Weather Service describes an ice storm as damaging accumulations of ice in freezing rain, generally about 1/4 inch or more, and says warning criteria vary by state. Ready.gov says winter storms can cut off heat, power, and communication services, and to gather supplies in case you need to stay home for several days without power.

  • Prepare before the forecast lands: insulation, caulking, and weather stripping, per Ready.gov.
  • Charge everything, and check your CO alarm batteries.
  • Clear the generator plan before the storm. Ready.gov says keep it dry and protected, and let it cool before refueling.
  • Stay away from downed lines. The Red Cross says they can electrocute you.
  • If you have a sump pump, freezing rain and a dead outlet can be a second problem. See sump pump battery backup.

The 72 hour emergency kit and power outage kit cover the supplies. The printable outage plan puts these rules on one sheet.

Know when cold has become an emergency

Ready.gov says a body temperature below 95 degrees is an emergency. Watch for shivering, exhaustion, confusion, fumbling hands, memory loss, slurred speech, or drowsiness. Keep the person dry and wrapped in warm blankets, including the head and neck, and get medical help.

For frostbite, Ready.gov lists numbness, white or grayish-yellow skin, and firm or waxy skin, and says not to massage the area or use a heating pad. CDC’s winter page says older adults are more susceptible to cold-related health problems and suggests an easy-to-read thermometer where you will see it often. CPSC asks neighbors to check on each other during long outages, and I would start with the older people on your road.

What I am not claiming

I have not tested these products or measured any of the runtimes above. They are arithmetic from catalog specs, one maker’s estimate, and a few printed labels. The furnace watts come from a chart reproduced by a retailer, and the mass.gov original would not open for me, so treat them as rough. I left out advice on frozen pipes, because the Red Cross page I could open named the topic without giving the steps. I am not an electrician or an HVAC technician. If a heat source burns fuel, follow its manual and vent it, and if a CO alarm sounds, get out first.

Frequently Asked Questions

How can I heat my house during a power outage?
Shut down the house to one room: close vents and doors in rooms you are not using, block drafts with rolled towels, open blinds in sun and close them at night, and dress in loose layers. A fireplace or wood stove can help if the chimney is sound and the flue is open. If you cannot keep the house warm, go to a warming center. Calling 211 can help you find one.
Can I use my gas oven or stove to heat the house?
No. Ready.gov, CDC, and the Red Cross all say not to. Ready.gov says it raises the risk of carbon monoxide poisoning, and that using an oven or stovetop for heat can also cause fires and burns and damage the appliance.
How far should a generator be from the house?
At least 20 feet. Ready.gov says at least 20 feet from windows, doors, and attached garages. CPSC says at least 20 feet from the house with the exhaust directed away from buildings. CDC says more than 20 feet from windows, doors, and vents. Never run one in a home, garage, basement, crawlspace, shed, or on a porch, even with doors and windows open.
Can a portable power station run a space heater?
Only briefly. A 1,500 W heater would drain a 1,152 Wh station in about 39 minutes using the 0.85 estimate, and a 300 W station cannot run it at all. An electric blanket at 200 W is a far better use of the same battery, at about 4.9 hours.
Can a power station run a furnace blower?
Sometimes, but it is not a plug-in job. Gas and propane furnaces need electricity for the blower and controls, and most are wired to a dedicated circuit, so connecting one is work for a licensed electrician or HVAC technician. A published chart puts furnace fans around 300 to 875 running watts, so read your own rating plate.
What are the symptoms of carbon monoxide poisoning?
CDC lists headache, dizziness, weakness, upset stomach, vomiting, chest pain, and confusion, and says symptoms are often flu-like. People who are asleep can die before they have symptoms. If you suspect CO or an alarm sounds, get outside immediately and then call 911.